The device is designed to restore the valve in conjunction with the adapter on nudepreventing coil. When designing the device, special attention was paid to reducing mass and dimensions, as well as the simplicity of the design.
Characteristics
- Working fluid type
- MINERAL OILS
- The dimensions of the overpressure coil on which the device is mounted and the valve is guided ([lower flange] - [upper flange] - [height]
- 180 × 21-18 × 21-240 ... 410 mm
- Working fluid consumption
- 3… 4 Dm3 / min
- Type of guided valve
- 65 mm × 21 MPa
- Maximum weight assembled (without guided valve and adapter)
- 16 Kg
- Working fluid pressure in the pressure line
- 5 ... 6 MPa
- Pointing adapter size ([bottom flange] - [top flange] - [height]
- 180 × 21-65 × 21-176 mm